Concrete Reinforcing Steel, grade B500C, of high strength and ductility, certified with the internationally recognized UK standard BS4449:2005. The iron strengthens the frame of a building and does not allow the concrete to fail and break the columns and beams thus enhancing the durability, strength and stability of the construction in the event of an earthquake.
The product is available in the following forms:
Name Diameter (mm) | Name Cross Section (mm2) | Tolerance (%) | Name Weight (kg/m) |
---|---|---|---|
8 | 50.3 | ±6 | 0.395 |
10 | 78.5 | ±4,5 | 0.617 |
12 | 113 | ±4,5 | 0.888 |
14 | 154 | ±4,5 | 1.210 |
16 | 201 | ±4,5 | 1.580 |
18 | 254 | ±4,5 | 2.000 |
20 | 314 | ±4,5 | 2.470 |
22 | 380 | ±4,5 | 2.980 |
25 | 491 | ±4,5 | 3.850 |
28 | 616 | ±4,5 | 4.830 |
32 | 804 | ±4,5 | 6.310 |
40 | 1257 | ±4,5 | 9.860 |
SPECIFICATION | QUALITY B500C |
---|---|
Leakage Limit, F Y (MPA) | ≥500 |
Ratio of actual to nominal value of the leakage limit, FY, ACT/FY,NOM | ≤1,25 |
Ratio of tensile strength to leakage limit, FT/FY | ≥1,15 ≤1,35 |
Total distortion (elongation) at maximum load (%) | ≥7,5 |